Heizlastprofi
TECHNICAL PLANNING · THROUGHOUT GERMANY

Underfloor heating design & laying plan

Heating circuits, pipe spacing and manifolds clearly planned.

We design the underfloor heating room by room according to DIN EN 1264: lowest flow temperature, pipe spacing, heating circuits, flow rate and settings at the manifold. You also receive the laying plan. Particularly important for heat pumps, which work efficiently at a low flow temperature.

Quote within minutes · Processing time: Within 2 days after our confirmation that the required documents are complete. · Questions only when absolutely necessary

Underfloor heating with two heating circuits and manifold
THE RESULT

What you receive.

  • Flow temperature and pipe spacing per room, with a check of the floor surface temperature
  • Heating circuits per manifold with pipe length, flow rate in l/h and l/min and settings
  • Laying plan and bill of materials; rooms that need an additional heating surface
  • Verifiable PDF report with all inputs, assumptions and sources, checked by experts

Basis: standards and regulations

  • DIN EN 1264-2 – heat output of underfloor heating
  • DIN EN 1264-3 – design
  • DIN EN 1264-4 – installation
  • DIN EN 12831-1:2017-09 with DIN/TS 12831-1:2020-04 – room-by-room heat load

Your plans are the basis. If areas, fixtures or floor coverings change later, the design may need to be adjusted.

Who is this service for?

Heating installers, builders and renovation projects. A single project or an extensive one: we agree the right scope.

NO FURTHER CALCULATION REQUIRED

Which basis is needed?

No additional service from our offer is required. What matters are the project documents listed below.

Recommended addition

Heat load calculation · recommended, not required

Recommended, but not required. We determine the room heat loads needed for this ourselves from your plans. You can quickly and easily add a complete heat load calculation, for example for sizing a heat pump; we are happy to use an existing calculation.

Additional services are not automatically included in the price shown and are agreed in advance.

Delivery time & price

Within 2 days after our confirmation that the required documents are complete.

from 349,00 € incl. VAT Bis 120 m² Fußbodenheizfläche. Die Raumwerte ermitteln wir aus Ihren Plänen; eine vorhandene Heizlastberechnung ist nicht erforderlich.

The specific quote is confirmed before the order is placed. Existing usable project data can reduce processing time and effort.

GOOD TO KNOW

Questions about the service.

Do we need a heat load calculation?

No. We determine the necessary room values from your plans. You can add a complete heat load calculation; we are happy to use an existing one.

What if the floor cannot fully heat a room?

The design shows this: we state the missing output, for example for a bathroom radiator, instead of raising the flow temperature for all rooms.

Which pipe spacing and which flow temperature?

We lay uniformly with 15 cm pipe spacing, 10 cm in the bathroom. From this we calculate the flow temperature that covers all living rooms; for heat pumps we point out if it is above 35 °C.

How quickly will I receive the quote and the result?

Das Angebot liegt in der Regel wenige Minuten nach der Anfrage mit Plänen in Ihrem Kundenkonto. Bearbeitungszeit: Within 2 days after our confirmation that the required documents are complete. Bei Leistungen mit Heizlast brauchen wir Baujahr und Fenster (am besten gleich im Anfrageformular); weitere Rückfragen stellen wir nur, wenn eine Angabe weder aus den Unterlagen noch aus Normwerten ableitbar ist.

COORDINATED WITH EACH OTHER

Suitable additions.

EVERY PROJECT IS WELCOME

What are you planning?

A single room or a complex system network – we listen and clarify the right scope of services.

Discuss your project