Heizlastprofi
TECHNICAL PLANNING · THROUGHOUT GERMANY

Radiator check

Are the existing radiators sufficient?

We compare the output of your existing radiators at 55/45, 50/40 and 45/35 °C or your planned system temperature with the heat demand of each room. This shows which radiators can continue to be used, how low the flow temperature may be and where output is missing.

Quote within minutes · Processing time: Within 2 days after our confirmation that the required documents are complete. · Questions only when absolutely necessary

THE RESULT

What you receive.

  • Coverage per room at 55/45, 50/40 and 45/35 °C or your planned temperature
  • Minimum flow temperature of the building and missing output per room
  • Required rated output for rooms that need adjustment
  • Verifiable PDF report with all inputs, assumptions and sources, checked by experts

Basis: standards and regulations

  • DIN EN 442-2 – rated heat output and conversion to other temperatures
  • VDI 6030 sheet 1 – installation situation of radiators
  • DIN EN 12831-1:2017-09 with DIN/TS 12831-1:2020-04 – room-by-room heat load
  • VDI 4645 – flow temperatures for heat pumps

The check shows where output is missing and which rated output is needed. The specific selection of new radiators with type, dimensions and order list is part of the radiator check and design service.

Who is this service for?

Owners and heating installers replacing a heating system. A single project or an extensive one: we agree the right scope.

NO FURTHER CALCULATION REQUIRED

Which basis is needed?

No additional service from our offer is required. What matters are the project documents listed below.

Recommended addition

Heat load calculation · recommended, not required

Recommended, but not required. We determine the room heat loads needed for this ourselves from your plans. You can quickly and easily add a complete heat load calculation, for example for sizing a heat pump; we are happy to use an existing calculation.

Additional services are not automatically included in the price shown and are agreed in advance.

Delivery time & price

Within 2 days after our confirmation that the required documents are complete.

from 149,00 € incl. VAT Bis 10 Heizkörper, Bewertung für 55/45, 50/40 und 45/35 °C oder Ihre geplante Systemtemperatur. Die raumweise Heizlast ermitteln wir dafür aus Ihren Plänen, eine vorhandene Heizlastberechnung ist nicht erforderlich.

The specific quote is confirmed before the order is placed. Existing usable project data can reduce processing time and effort.

GOOD TO KNOW

Questions about the service.

Does every radiator have to be replaced with a heat pump?

This can only be judged room by room. What matters are the heat load, existing heating surfaces and the planned temperatures.

Do we need a heat load calculation?

No. We determine the room heat loads needed for the check from your plans. We are happy to use an existing heat load calculation; if needed, you can quickly and easily add a complete heat load calculation.

How quickly will I receive the quote and the result?

Das Angebot liegt in der Regel wenige Minuten nach der Anfrage mit Plänen in Ihrem Kundenkonto. Bearbeitungszeit: Within 2 days after our confirmation that the required documents are complete. Bei Leistungen mit Heizlast brauchen wir Baujahr und Fenster (am besten gleich im Anfrageformular); weitere Rückfragen stellen wir nur, wenn eine Angabe weder aus den Unterlagen noch aus Normwerten ableitbar ist.

COORDINATED WITH EACH OTHER

Suitable additions.

EVERY PROJECT IS WELCOME

What are you planning?

A single room or a complex system network – we listen and clarify the right scope of services.

Discuss your project