Pipe network calculation

Pipe sizes and pressure losses under control.

We calculate the heating pipe network section by section: flow rate, pipe size, flow velocity and pressure loss, plus the least favourable circuit, the pump head and the valve values. We size new networks and check existing ones – for example when switching to a heat pump.

Quote within minutes · Processing time: Within 2 days after our confirmation that the required documents are complete. · Questions only when absolutely necessary

Heating pipe network with radiators, pipe diameter, flow rate and pressure loss
THE RESULT

What you receive.

  • Pipe size, velocity and pressure loss per section
  • Least favourable circuit and pump head
  • Valve values per heating surface; for existing systems the sections that need adjustment
  • Verifiable PDF report with all inputs, assumptions and sources, checked by experts

Basis: standards and regulations

  • VDI 2073 sheet 1 – hydraulics in building services systems
  • Pressure loss according to Darcy-Weisbach with Colebrook-White
  • DIN EN 12831-1:2017-09 with DIN/TS 12831-1:2020-04 – room-by-room heat load

This service concerns heating pipe networks. Drinking water networks, with their own requirements, are handled through the drinking water calculation.

Who is this service for?

Heating installers, planning offices and wholesalers. A single project or an extensive one: we agree the right scope.

NO FURTHER CALCULATION REQUIRED

Which basis is needed?

No additional service from our offer is required. What matters are the project documents listed below.

Recommended addition

Heat load calculation · recommended, not required

Recommended, but not required. We determine the room heat loads needed for this ourselves from your plans. You can quickly and easily add a complete heat load calculation, for example for sizing a heat pump; we are happy to use an existing calculation.

Additional services are not automatically included in the price shown and are agreed in advance.

Delivery time & price

Within 2 days after our confirmation that the required documents are complete.

from 349,00 € incl. VAT Für ein Wohnhaus mit bis zu 10 Heizflächen. Die Raumwerte ermitteln wir aus Ihren Plänen; eine vorhandene Heizlastberechnung ist nicht erforderlich.

The specific quote is confirmed before the order is placed. Existing usable project data can reduce processing time and effort.

GOOD TO KNOW

Questions about the service.

Can the calculation also be done for existing systems?

Yes. We check recognisable sizes for velocity and pressure gradient; unknown pipe routes are derived from the floor plans and marked as an assumption.

Do we need a riser diagram?

No. We are happy to use an existing riser diagram; otherwise we derive the pipe routing from your plans.

Do we need a heat load calculation?

No. We determine the necessary room values from your plans. We are happy to use an existing heat load calculation.

Is the result a detailed execution design?

If a riser diagram, pipe system and manufacturer data are available, we calculate all sections with their fittings in detail. If they are missing, you receive a preliminary sizing marked as such, with documented assumptions; sizes and pump head must then be confirmed before execution.

How quickly will I receive the quote and the result?

Das Angebot liegt in der Regel wenige Minuten nach der Anfrage mit Plänen in Ihrem Kundenkonto. Bearbeitungszeit: Within 2 days after our confirmation that the required documents are complete. Bei Leistungen mit Heizlast brauchen wir Baujahr und Fenster (am besten gleich im Anfrageformular); weitere Rückfragen stellen wir nur, wenn eine Angabe weder aus den Unterlagen noch aus Normwerten ableitbar ist.

COORDINATED WITH EACH OTHER

Suitable additions.

EVERY PROJECT IS WELCOME

What are you planning?

A single room or a complex system network – we listen and clarify the right scope of services.

Discuss your project