Heat load calculation
The right output, room by room.
A room-by-room heat load calculation shows what heating output a building and its individual rooms need on the design day. It creates the basis for heat generators, heating surfaces and hydraulic balancing – in new buildings and existing ones.
Quote within minutes · Processing time: Within 2 days after our confirmation that the required documents are complete. · Questions only when absolutely necessary
What you receive.
- Room-by-room heat load and building heat load
- Component documentation with U-values, ventilation approach and boundary conditions
- Basis for sizing heat generators and heating surfaces
- Verifiable PDF report with all inputs, assumptions and sources, checked by experts; your plans as an appendix
Basis: standards and regulations
- DIN EN 12831-1:2017-09 – method for calculating the design heat load
- DIN/TS 12831-1:2020-04 – national supplement (climate data, room temperatures, ventilation)
- DIN EN ISO 6946 – U-values from the component build-up
- DIN 4108-4 and DIN 4108 supplement 2 – design values and thermal bridges
We set missing component data according to the year of construction with the usual values of that period and show them in the report as an assumption. Flat-rate consumption values do not replace a room-by-room calculation.
Who is this service for?
Owners, heating installers, planners and wholesalers. A single project or an extensive one: we agree the right scope.
Which basis is needed?
No additional service from our offer is required. What matters are the project documents listed below.
Additional services are not automatically included in the price shown and are agreed in advance.
Delivery time & price
Within 2 days after our confirmation that the required documents are complete.
from 349,00 € incl. VAT Für ein Wohnhaus bis 249 m² mit bemaßten Plänen. Bei größeren Gebäuden steigt der Preis mit der Fläche.
The specific quote is confirmed before the order is placed. Existing usable project data can reduce processing time and effort.
Questions about the service.
Which method is used for the calculation?
Room by room according to DIN EN 12831-1:2017-09 with the national annex DIN/TS 12831-1:2020-04. We determine U-values from your component build-ups according to DIN EN ISO 6946; if they are missing, we use the usual values of the construction period and show them as an assumption.
I have no U-values or component build-ups. Is it still possible?
Yes. We only ask you for the year of construction and your windows (double or triple glazing, approximate year of installation). We set all other values according to the standard and the construction period.
Are photos enough?
For the calculation we need floor plans with dimensions or scale. Photos help with windows and components, but do not replace plans.
Do I need the heat load calculation for a funding application?
For hydraulic balancing according to procedure B, for example for BEG funding, a room-by-room heat load calculation is required. For this there is the package heat load calculation + hydraulic balancing with a pre-filled VdZ form.
How quickly will I receive the quote and the result?
Das Angebot liegt in der Regel wenige Minuten nach der Anfrage mit Plänen in Ihrem Kundenkonto. Bearbeitungszeit: Within 2 days after our confirmation that the required documents are complete. Bei Leistungen mit Heizlast brauchen wir Baujahr und Fenster (am besten gleich im Anfrageformular); weitere Rückfragen stellen wir nur, wenn eine Angabe weder aus den Unterlagen noch aus Normwerten ableitbar ist.
Suitable additions.
What are you planning?
A single room or a complex system network – we listen and clarify the right scope of services.