Heizlastprofi
TECHNICAL PLANNING · THROUGHOUT GERMANY

Radiator check and design

Check existing radiators and choose suitable new ones.

We check whether your existing radiators are sufficient at the planned system temperature and specify new radiators for every room lacking output: type, height, length and connection, matching the available wall space. Your installer receives a list to order and install from.

Quote within minutes · Processing time: Within 2 days after our confirmation that the required documents are complete. · Questions only when absolutely necessary

Room with radiator and underfloor heating, heat demand and available heating output compared
THE RESULT

What you receive.

  • Everything from the radiator check: coverage per room, minimum flow temperature, missing output
  • Specific radiator selection per room with type, dimensions, rated output and connection
  • Order list for the installer and documented design temperatures
  • Verifiable PDF report with all inputs, assumptions and sources, checked by experts

Basis: standards and regulations

  • DIN EN 442-2 – rated heat output and conversion to other temperatures
  • VDI 6030 sheet 1 – design and installation situation of radiators
  • DIN EN 12831-1:2017-09 with DIN/TS 12831-1:2020-04 – room-by-room heat load
  • VDI 4645 – flow temperatures for heat pumps

We offer the planning of underfloor heating with a laying plan as a separate service.

Who is this service for?

Heating installers, builders and renovation projects. A single project or an extensive one: we agree the right scope.

NO FURTHER CALCULATION REQUIRED

Which basis is needed?

No additional service from our offer is required. What matters are the project documents listed below.

Recommended addition

Heat load calculation · recommended, not required

Recommended, but not required. We determine the room heat loads needed for this ourselves from your plans. You can quickly and easily add a complete heat load calculation, for example for sizing a heat pump; we are happy to use an existing calculation.

Additional services are not automatically included in the price shown and are agreed in advance.

Delivery time & price

Within 2 days after our confirmation that the required documents are complete.

from 199,00 € incl. VAT Für bis zu 10 Räume. Die Raumwerte ermitteln wir aus Ihren Plänen, eine vorhandene Heizlastberechnung ist nicht erforderlich.

The specific quote is confirmed before the order is placed. Existing usable project data can reduce processing time and effort.

GOOD TO KNOW

Questions about the service.

What is the difference from the radiator check?

The radiator check shows whether the existing radiators are sufficient and how much output is missing. The radiator check and design also selects the new radiators specifically – with type, dimensions, connection and order list.

Do we need a heat load calculation?

No. We determine the necessary room values from your plans. We are happy to use an existing heat load calculation.

Is an underfloor heating laying plan included?

No. For this, choose the separate service underfloor heating design & laying plan.

How quickly will I receive the quote and the result?

Das Angebot liegt in der Regel wenige Minuten nach der Anfrage mit Plänen in Ihrem Kundenkonto. Bearbeitungszeit: Within 2 days after our confirmation that the required documents are complete. Bei Leistungen mit Heizlast brauchen wir Baujahr und Fenster (am besten gleich im Anfrageformular); weitere Rückfragen stellen wir nur, wenn eine Angabe weder aus den Unterlagen noch aus Normwerten ableitbar ist.

COORDINATED WITH EACH OTHER

Suitable additions.

EVERY PROJECT IS WELCOME

What are you planning?

A single room or a complex system network – we listen and clarify the right scope of services.

Discuss your project