HAMBURG

Heat load calculation in Hamburg

In Hamburg, 54.5 % of homes are heated with gas and 35 % with district heating, and 66.2 % of buildings with living space date from before 1979. According to the heat plan, around 78 % of all buildings are to be supplied in a decentralised way in future, mainly with heat pumps. For the heat pump, the room-by-room heat load is the basis.

Buildings and heating systems in Hamburg

BUILT BEFORE 1979

66,2 %

260.630 Buildings with living space, of which this share was built before the first Thermal Insulation Ordinance (Wärmeschutzverordnung)
GAS HEATING

54,5 %

985.422 Homes, of which this share are heated with gas
HEATING OIL

7,2 %

Share of homes with oil heating
DISTRICT HEATING

35,0 %

Share of homes with district heating

Source: Zensus 2022, Statistische Ämter des Bundes und der Länder – Gemeindeergebnisse Hamburg (aufbereitet von wahlatlas.net), Reference date 15.05.2022

Heat planning and heating replacement in Hamburg

What this means for your house

For around 78 % of Hamburg's buildings, the heat plan envisages individual, decentralised supply – usually with a heat pump; heating networks are growing mainly in Wilhelmsburg, Rothenburgsort, Veddel and the eastern HafenCity. The room-by-room heat load calculation shows what output your house needs and whether your radiators are sufficient.

Frequently asked questions from Hamburg

Will my district of Hamburg get a heating network?

The heat plan map in the city's heat portal shows this: it indicates the most suitable supply for each area. For houses in areas with decentralised supply, we calculate the heat load for a heat pump.

Do you come to my home for the heat load calculation?

No, that is not necessary. You upload floor plans, sections and photos online – for a house in Hamburg just as anywhere else in Germany. If anything is missing, we ask for it specifically.

How quickly will I receive the result?

You receive your quote within a few minutes. We deliver the expert-checked result within 2 days of our confirmation that the required documents are complete.

Is the calculation sufficient for KfW funding?

Yes. The room-by-room heat load calculation according to DIN EN 12831-1 and hydraulic balancing according to procedure B are the evidence required for heat pump funding.