Heat load calculation in Hanover

In Hanover, 77.2 % of homes are heated with gas and 17.1 % with district heating, and 69.9 % of residential buildings date from before 1979. The heat plan adopted in 2025 relies on more district heating in the dense city and on decentralised solutions such as heat pumps in less densely built-up areas. For the heat pump, the room-by-room heat load is the basis.

Buildings and heating systems in Hanover

BUILT BEFORE 1979

69,9 %

70.271 Buildings with living space, of which this share was built before the first Thermal Insulation Ordinance (Wärmeschutzverordnung)
GAS HEATING

77,2 %

302.018 Homes, of which this share are heated with gas
HEATING OIL

3,7 %

Share of homes with oil heating
DISTRICT HEATING

17,1 %

Share of homes with district heating

Source: Zensus 2022, Statistische Ämter des Bundes und der Länder – Gemeindeergebnisse Hannover (aufbereitet von wahlatlas.net), Reference date 15.05.2022

Heat planning and heating replacement in Hanover

What this means for your house

In Hanover, detached and two-family houses are generally not considered suitable for district heating; here the city recommends looking into a heat pump. The room-by-room heat load calculation shows what output is required and whether your radiators can supply every room at a low flow temperature – exactly the proof that proKlima, for example, requires.

Frequently asked questions from Hanover

Do I have to connect my house in Hanover to district heating?

There is a connection obligation only in the bylaw area, only from a total rated heat output of 25 kW and only in the event of major alterations or when the heating is replaced. An exemption can be applied for for emission-free installations such as heat pumps; enercity's map shows whether your address is in the bylaw area.

Do you come to my home for the heat load calculation?

No, that is not necessary. You upload floor plans, sections and photos online – for a house in Hanover just as anywhere else in Germany. If anything is missing, we ask for it specifically.

How quickly will I receive the result?

You receive your quote within a few minutes. We deliver the expert-checked result within 2 days of our confirmation that the required documents are complete.

Is the calculation sufficient for KfW funding?

Yes. The room-by-room heat load calculation according to DIN EN 12831-1 and hydraulic balancing according to procedure B are the evidence required for heat pump funding.

Sources

All information about the city is publicly available data from the bodies named (retrieved on 19.11.2026). The city and the energy supplier decide on connection to a heating network; the heat load calculation itself applies to your building regardless.

More cities in Lower Saxony

Heat load calculation in Brunswick · Heat load calculation in Celle · Heat load calculation in Delmenhorst · Heat load calculation in Garbsen · Heat load calculation in Göttingen · Heat load calculation in Hamelin · Heat load calculation in Hildesheim · Heat load calculation in Langenhagen · Heat load calculation in Lingen · Heat load calculation in Lüneburg · Heat load calculation in Nordhorn · Heat load calculation in Oldenburg · Heat load calculation in Osnabrück · Heat load calculation in Peine · Heat load calculation in Salzgitter · Heat load calculation in Wilhelmshaven · Heat load calculation in Wolfenbüttel · Heat load calculation in Wolfsburg · All cities